Design flaws to look out for when purchasing an Ozone Machine

Due to the recent outbreak of Covid 19 the purchase of Ozone machines has never been so popular due to the potential anti-viral properties alongside the tried and tested Odour Control applications.

We at Ozone Clean are at the forefront of Manufacturing and researching in Ozone technology and have had numerous enquiries as to what you need to look out for with regards to efficiency and reliability in an Ozone Generator.

This has come about due to many companies with little or no experience in manufacturing and researching Ozone technology supplying machines that have very basic design flaws in the above areas.

Due to these enquires and as a specialist in this field we have compiled a list of potential design flaws to look out for alongside the negative consequences and solutions of these flaws.

Design or Information Problem

Consequence

Solution

Not having an Ozone destruct part of the treatment cycle when emitting over 0.2 PPM (Safe level of Ozone)

  • Having to leave the area treated while the Ozone reverts back to oxygen. This can take many hours
  • The need to buy an Ozone Meter to check the levels are safe to enter.
  • Having to wear PPE when entering to test levels
  • Strong residual smell of Ozone
  • Increase in labour costs of above
  • Potential H&S issues of entering area with unsafe levels of Ozone
  • Choose reliable supplier with proven track record
  • Make sure unit removes or destroys the Ozone at the end of the cycle
  • Request tested proof of removal and level of Ozone at the end of the cycle.
  • Do your research and pay for quality and reliability

Not having a middle “dwell” part of the cycle.
An efficient, powerful Ozone machine should have 3 parts to each cycle.
Produce/Dwell/Destroy

  • Without the dwell period the process is to Produce then immediately destroy the Ozone.
  • As Ozone is heavier than air it needs time to circulate and then fall to the floor covering all the surfaces and penetrating the furnishings
  • If the unit is destroying the Ozone straight after the production the Ozone will not have the time to fall to the floor and settle on surfaces and penetrate fabrics
  • 45-65% of efficiency lost as the Ozone will not be able to control the Infection or Odour through the Cell Lysing process
  • Obtain product literature
  • Check 3 part cycle and not 2 part
  • Request cycle breakdown i.e Production/Dwell/Removal ratios
  • Removal needs to be longer than production
  • Ratio should be approx. 3/8:1/8:4/8

Ozone output not through the top of the machine

  • As Ozone is heavier than air it will immediately fall to the floor
  • The height of the placement of the unit will be the highest part of treatment
  • For example if it is left on a table or chair then only the height of table or chair to the floor will get treated
  • Odours, Bacteria and viruses become airborne as well as settling on curtains and walls and will not be treated
  • Half the area gets treated
  • Purchase a unit where the Ozone comes out of the top or chimney with a powerful fan.
  • This creates the “Volcano Effect” of the gas reaching the ceiling, spreading across and falling to the floor
  • Ask supplier where the Ozone is emitted

Bespoke H&S Lab testing on each unit produced

  • Many machines claim to bring the Ozone level back to below the 0.2PPM level
  • Without testing under controlled circumstances with an accurate Ozone meter for each machine built the residual Ozone may be higher than the recommended level
  • Either no or generic lab test is supplied
  • Ask supplier for testing
    Make sure date and time is bespoke to your purchase
  • Do not purchase if not supplied as occupants may be exposed to a level of Ozone that is not recommended.

Too high Ozone output with insufficient catalyst.

  • Beware of Ozone machines that are the same size with variable Ozone outputs
  • If the unit is the same size but can produce variable Ozone outputs then the same amount of catalysts may not be able to destroy the Ozone totally
  • This could result in occupants entering an area with too high levels of Ozone
  • We recommend at least 1 x catalyst per 5g of Ozone produced
  • Ask supplier how many catalysts are utilised in the machine

Complicated operation

  • Incorrect use
  • Negative results
  • H&S implications
  • Request product literature
  • Check user friendly
  • Visible On-Screen instructions
  • Minimal buttons
  • Comprehensive manual

No “Self Service” option.

  • Concern of reliability
  • High expense
  • Lower ROI
  • Unit unavailable for service period
  •  Loss of efficiency
  • Ask supplier for option
  • Choose supplier with the option even if you do not use it

No Testimonials, Case Studies or Client list supplied

  • Lack of experience
  • No track record
  • No point of contact
  • Unprofessional customer service
  • Unreliable equipment
  • Ask supplier for details
  • Avoid supplier if cannot provide or is unsatisfactory

No “Wait” time before Ozone production.

  • H&S implications as the unit will start the Ozone production while operator is still in the room
  • Exposure to high levels of Ozone
  • An Ozone Machine should have a “wait period” before the Ozone is being produced giving the operator time to vacate the area
  • Ask supplier

Plastic construction

  • Cracks and splits on impact
  • Ozone leakage – H&S issues
  • Not durable over time
  • Short Life span
  • Choose unit with metal construction
  • Aluminium recommended

UV lamp Ozone production

  • Harder to control Ozone output
  • UV health implications
  • Lamp breaks on impact
  • Choose unit that uses Corona discharge method through dielectric plates

Non ambient air conditions

  • If an Ozone generator does not use ambient air conditions, which means it utilises the air in the room to transform into Ozone then you will have to purchase Oxygen canisters to produce the Ozone
  • Extra expense
  • Reliance on supplier to deliver on time
  • Higher breakdown rate
  • Ask the supplier how the equipment produces the Ozone
  • If not ambient nor canister contact Ozone Clean for advice

We have compiled this list for your benefit only. This list is not to persuade you to buy from Ozone Clean only but to make sure you make the right decision for your organisation or home. Please be advised that the information provided is our opinion based on over 15 years of manufacturing experience in this field as well as continuous research and development of our products.

Ozone is a very safe application for Odour and Infection Control but used incorrectly or with a sub-standard machine could result in lack of satisfaction or health and safety issues.

Ozone Clean advocates the fantastic applications of Ozone and would be happy to confirm or refute any other models safety, efficiency and reliability, so please feel free to get in touch with any questions about our OC range and/or any other companies equipment for a peace of mind and informed decision which we highly recommend.